Start with the room, utilities and rack count. Use the tools below to plan climate conditions, rack-only electrical load and the information needed for a SkyAcres room review.

Your working plan

Plan each room separately

Name a site, enter its measurements and choose the crop. Rack count and readiness checks below stay with this plan.

The rack count also updates the electrical estimates below. Changing it clears load and layout confirmations for review.

The optional support allowance subtracts space reserved inside this room for storage, washing or other support work. Aisles are accounted for separately in the remaining growing zone's 60% rack / 40% circulation allowance. Enter door and ceiling measurements to flag access constraints.

Add room measurements
Inside room area
Not entered
Growing zone after support space
Not entered
Estimated capacity
Not yet calculated

Enter length and width to compare the room with your rack count.

    This is an area estimate. Room shape, columns, door positions, service clearance and local exit requirements still need a layout review. A 6 ft rack height is not a recommended ceiling height.

    View room brief

    Changes save in this browser.

    A snapshot link includes this site's name, measurements, notes and checklist. Anyone with the link can open those details. Only share information intended for the recipient.

    01

    At a glance

    Facility starting points

    68 to 70°F20 to 21°C daytime
    60% RHPlanning humidity
    120 VStandard rack supply
    1.3 APlanning load per rack
    9 or 12Racks per 15 A or 20 A circuit
    3 × 7 ftMinimum clear door
    3 × 1.5 × 6 ftRack size, with a 4.5 sq ft footprint
    60 / 40Rack area / walkways
    Strong signalInternet throughout grow rooms
    02

    Build the operating core

    Six things to settle before equipment delivery.

    01

    A clean, sealed room

    Close gaps in walls and ceilings so the room holds temperature and keeps pests out. Confirm service aisles and exits locally.

    02

    A stable crop zone

    Hold the target temperature and humidity with building HVAC or a SkyAcres controller operating portable climate equipment.

    03

    Standard power

    All rack equipment uses 120 V power. Plan up to 1.3 A per rack in a two-light configuration.

    04

    Clean water

    Use reverse osmosis water and make sure a hose reaches every planned refill point.

    05

    Strong room internet

    Provide reliable internet coverage throughout the growing rooms. It does not need to be tested at every rack position.

    06

    Room to move

    The minimum clear door is 3 ft wide by 7 ft high. We prefer 3 ft 6 in by 7 ft 6 in, plus a clear pallet route for larger sites.

    03

    Plan the crop climate

    Convert temperatures and choose how the room will hold them.

    Temperature converter

    General day range68 to 70°F20 to 21°C
    Warm target73°F23°C
    Mixed-crop night minimum56°F13°C
    Strawberry night range50 to 55°F10 to 13°C
    Option A

    Building HVAC

    Use the building's HVAC system when it can maintain the crop zone efficiently and consistently.

    Option B

    SkyAcres controller

    Use the SkyAcres controller to operate a series of low-cost portable heaters, air conditioners, humidifiers and dehumidifiers.

    Early dehumidification allowance0.4 L

    Per rack, per day. Use this for early budgeting, then size final equipment for crop, canopy, room leakage and outdoor conditions.

    Example strawberry day to night delta15°F / 8°C

    A 70°F day and 55°F night is one useful planning example within the current crop guidance.

    Climate depends on the crop

    For a mixed-crop room, plan for nights at 56°F (13°C) or warmer, with separate cooler zones where needed. Strawberries need a meaningful daytime and nighttime difference. Current SkyAcres crop guidance is about 65 to 75°F, or 18 to 24°C, by day and 50 to 55°F, or 10 to 13°C, at night. Confirm the final setpoints for the variety and growth stage.

    Young plants may need added humidity. Established plants release moisture and may need dehumidification. Use separate poly-film zones where crops need different conditions. Tomatoes may also need their own zone.

    04

    Calculate rack power and estimated area

    Rack load only. Climate, water and room equipment are separate. Area assumes 60% racks and 40% walkways.

    162.5 ARack running current1.3 A × 125 racks
    19.5 kWRack running powerAt 120 V
    14 circuits15 A circuit planUp to 9 racks each
    11 circuits20 A circuit planUp to 12 racks each
    563 sq ftRack footprint4.5 sq ft per rack
    938 sq ftEstimated total room area60% racks / 40% walkways
    Dedicated rack circuits

    Do not share rack circuits with climate equipment, pumps, sinks, office loads or general receptacles.

    Separate support circuits

    Plan independent capacity for HVAC, heaters, AC units, humidifiers, dehumidifiers, reverse osmosis equipment and work areas.

    Constant rack power

    Rack controllers manage the growing equipment. Do not place rack receptacles on switched lighting circuits.

    Planning basis: up to 1.3 A per rack in a two-light configuration. A licensed electrician must confirm the final panel, conductor, breaker, balancing and service design.

    Further reading: single-phase, split-phase and three-phase service

    SkyAcres racks are 120 V loads. The 1.3 A planning load per rack stays the same across common service types. What changes is how branch circuits are distributed and how the upstream service is sized.

    • Single-phase: rack circuits are supplied from a single-phase system.
    • Split-phase: most North American 120/240 V services provide two 120 V legs sharing a neutral. An electrician balances rack circuits across both legs. Split-phase is sometimes casually called two-phase, although true two-phase service is uncommon.
    • Three-phase: where the panel provides 120 V line-to-neutral, an electrician can distribute rack circuits across the available phases and balance the load.

    Do not divide the calculated rack current by two or three to select a service. Neutral loading, continuous-load rules and all climate loads belong in the final electrical design.

    05

    Plan utilities, monitoring and access

    The details that keep daily farm work reliable.

    Water, washing and drainage

    • A water test plus documented static and flowing pressure
    • A hose or fill point that reaches every rack without crossing unsafe paths
    • SkyAcres selects the water treatment and storage system after reviewing the site information and rack count
    • A large laundry or industrial sink to speed up strawberry crown processing and equipment washing
    • Washable surfaces and a protected floor drain where permitted
    • Freeze protection for water lines and storage in cold climates

    Connectivity and monitoring

    • Strong, reliable internet coverage throughout the growing rooms
    • Coverage confirmed after walls, insulation, racks and equipment are installed
    • Cameras where remote visual checks are useful
    • Temperature, humidity, leak and power-loss alerts
    • Controlled access and entry logging for shared or public facilities

    Access and material movement

    • Minimum clear door opening of 3 ft wide by 7 ft high
    • Preferred clear opening of 3 ft 6 in wide by 7 ft 6 in high
    • A continuous delivery path from unloading point to final rack location
    • Turning room, aisle width, floor loading and elevator capacity confirmed before delivery
    • Dedicated areas for receiving, storage, germination, harvest, packing, sanitation and cold storage as the operation requires
    06

    Separate essentials from resilience

    Build the operating core first, then improve workflow and redundancy.

    Plan from day one

    The operating core

    • Sealed crop space
    • Temperature and humidity control
    • Dedicated electrical circuits
    • Reverse osmosis water
    • Strong internet throughout the growing rooms
    • Safe doors, aisles and exits
    07

    Check room readiness

    Checks apply to the selected site and crop. Record essentials separately from recommended improvements.

    68 to 70°F by day. At night, plan for 56°F or warmer, with separate cooler zones where needed.

    Room readiness0 of 12 essentials recorded0 of 6 recommendations recorded
    Operating essentials
    Resilience and workflow
    08

    Turn your dimensions into a floor plan

    Send the information below. SkyAcres can prepare a floor plan and map out proposed outlet locations for your electrician to review.

    01Complete site dimensions
    02Planned rack count and crops
    03The electrical panel schedule
    04Water pressure and quality
    05Winter and summer room conditions
    06Internet coverage in the growing rooms
    07The loading-door delivery route
    08Local code and permitting contacts

    Rack count alone does not determine room size or mechanical capacity. Crop mix, working aisles, fire exits, germination, harvest handling, outdoor climate and future expansion all change the answer. Final electrical, mechanical, drainage and code designs must be confirmed for the site and local jurisdiction.

    SkyAcres facility planning

    Your room brief

    Room 1

    Last edited: . Planning snapshot for site review.

    Crop and climate
    Rack count
    125
    Room measurements
    Not entered
    Clear door opening
    Not entered
    Area comparison
    Rack electrical load
    Site notes and questions
    None entered.

    Items still to confirm

      Recorded by the planner user

        Area basis: 4.5 sq ft per rack, with 60% of the growing zone occupied by racks. Electrical basis: up to 1.3 A per rack at 120 V in a two-light configuration. Climate equipment, water treatment and work areas need separate capacity.

        This brief records planning inputs and user-checked items. SkyAcres and the site's qualified contractors must confirm the final layout, crop setpoints, electrical and mechanical sizing, drainage and local requirements before construction.

        skyacres.ag/facility-requirements/ | info@skyacres.ca

        Let us plan the room with you.

        Send us the room dimensions, door locations, crops and rack count. SkyAcres can create a floor plan and map out proposed outlet locations for your electrician to review.

        Request a Floor Plan