A clean, sealed room
Close gaps in walls and ceilings so the room holds temperature and keeps pests out. Confirm service aisles and exits locally.
Facility Planner
Start with the room, utilities and rack count. Use the tools below to plan climate conditions, rack-only electrical load and the information needed for a SkyAcres room review.
Your working plan
Name a site, enter its measurements and choose the crop. Rack count and readiness checks below stay with this plan.
The rack count also updates the electrical estimates below. Changing it clears load and layout confirmations for review.
The optional support allowance subtracts space reserved inside this room for storage, washing or other support work. Aisles are accounted for separately in the remaining growing zone's 60% rack / 40% circulation allowance. Enter door and ceiling measurements to flag access constraints.
Enter length and width to compare the room with your rack count.
This is an area estimate. Room shape, columns, door positions, service clearance and local exit requirements still need a layout review. A 6 ft rack height is not a recommended ceiling height.
Changes save in this browser.
A snapshot link includes this site's name, measurements, notes and checklist. Anyone with the link can open those details. Only share information intended for the recipient.
At a glance
Six things to settle before equipment delivery.
Close gaps in walls and ceilings so the room holds temperature and keeps pests out. Confirm service aisles and exits locally.
Hold the target temperature and humidity with building HVAC or a SkyAcres controller operating portable climate equipment.
All rack equipment uses 120 V power. Plan up to 1.3 A per rack in a two-light configuration.
Use reverse osmosis water and make sure a hose reaches every planned refill point.
Provide reliable internet coverage throughout the growing rooms. It does not need to be tested at every rack position.
The minimum clear door is 3 ft wide by 7 ft high. We prefer 3 ft 6 in by 7 ft 6 in, plus a clear pallet route for larger sites.
Convert temperatures and choose how the room will hold them.
Temperature converter
Per rack, per day. Use this for early budgeting, then size final equipment for crop, canopy, room leakage and outdoor conditions.
A 70°F day and 55°F night is one useful planning example within the current crop guidance.
For a mixed-crop room, plan for nights at 56°F (13°C) or warmer, with separate cooler zones where needed. Strawberries need a meaningful daytime and nighttime difference. Current SkyAcres crop guidance is about 65 to 75°F, or 18 to 24°C, by day and 50 to 55°F, or 10 to 13°C, at night. Confirm the final setpoints for the variety and growth stage.
Young plants may need added humidity. Established plants release moisture and may need dehumidification. Use separate poly-film zones where crops need different conditions. Tomatoes may also need their own zone.
Rack load only. Climate, water and room equipment are separate. Area assumes 60% racks and 40% walkways.
Do not share rack circuits with climate equipment, pumps, sinks, office loads or general receptacles.
Plan independent capacity for HVAC, heaters, AC units, humidifiers, dehumidifiers, reverse osmosis equipment and work areas.
Rack controllers manage the growing equipment. Do not place rack receptacles on switched lighting circuits.
Planning basis: up to 1.3 A per rack in a two-light configuration. A licensed electrician must confirm the final panel, conductor, breaker, balancing and service design.
SkyAcres racks are 120 V loads. The 1.3 A planning load per rack stays the same across common service types. What changes is how branch circuits are distributed and how the upstream service is sized.
Do not divide the calculated rack current by two or three to select a service. Neutral loading, continuous-load rules and all climate loads belong in the final electrical design.
The details that keep daily farm work reliable.
Build the operating core first, then improve workflow and redundancy.
Checks apply to the selected site and crop. Record essentials separately from recommended improvements.
68 to 70°F by day. At night, plan for 56°F or warmer, with separate cooler zones where needed.
Send the information below. SkyAcres can prepare a floor plan and map out proposed outlet locations for your electrician to review.
Rack count alone does not determine room size or mechanical capacity. Crop mix, working aisles, fire exits, germination, harvest handling, outdoor climate and future expansion all change the answer. Final electrical, mechanical, drainage and code designs must be confirmed for the site and local jurisdiction.
SkyAcres facility planning
Room 1
Last edited: . Planning snapshot for site review.
Area basis: 4.5 sq ft per rack, with 60% of the growing zone occupied by racks. Electrical basis: up to 1.3 A per rack at 120 V in a two-light configuration. Climate equipment, water treatment and work areas need separate capacity.
This brief records planning inputs and user-checked items. SkyAcres and the site's qualified contractors must confirm the final layout, crop setpoints, electrical and mechanical sizing, drainage and local requirements before construction.
skyacres.ag/facility-requirements/ | info@skyacres.ca
Send us the room dimensions, door locations, crops and rack count. SkyAcres can create a floor plan and map out proposed outlet locations for your electrician to review.
Request a Floor Plan